Model 9000/9100/9500 Service ManualIMPORTANT: Fill in pertinent information on page 3 for future reference.
Model 9000/9100/9500 10Time Brine Refill and Meter Setting ProcedureProgramming1. The control valve is set at the factory for backwash; brine and slo
Model 9000/9100/950011Example:Unit is set for a 16" diameter tank with 4 ft3 of resin and salted at 8 lbs. per ft3, 7 gpm backwash, #3 injector,
Model 9000/9100/9500 12ET Timer Installation And Start-Up Procedures1. In Normal Operation the Time Of Day and, if flow meter equipped, the Volume Re
Model 9000/9100/950013— When the first cycle step is reached, a red LED turns on indicating the current Regeneration cycle step.— Press the Extra Cycl
Model 9000/9100/9500 14ET Timer Control Start-Up ProcedureDisplay ETFigure 10:ET Timer DisplayIn Normal operation the Time Of Day display alternates
Model 9000/9100/950015ET Timer Control OperationTimeclock Regeneration ValvesWhen the number days since the last Regeneration reaches the preset numbe
Model 9000/9100/9500 16Start an Extra CyclePress the Extra Cycle button to start an Extra Regeneration tonight. Press and hold the Extra Cycle button
Model 9000/9100/950017Press the Extra Cycle button during a Regeneration cycle to immediately advances the valve to the next cycle step position and r
Model 9000/9100/9500 18SE Timer Control Start-Up ProceduresDisplay SEIn normal operation the Time Of Day display alternates with Volume Remaining and
Model 9000/9100/950019Set Control Programming1. Press and hold both the Set Up and Set Down buttons for 5 seconds.2. Set the Treated Water Capacity. U
IMPORTANT: The information, specifications and illustrations in this manual are based on the latest information available at the time of printing. The
Model 9000/9100/9500 20Immediate Regeneration Valves With Days Between Regeneration Override SetWhen the valve reaches its set Days Since Regeneratio
Model 9000/9100/950021ET and SE Timer AssembliesFigure 20Item Quantity Part Number Description1 1 configured itemET timer assembly2 1 configured itemS
Model 9000/9100/9500 229000/9100/9500 Electro Mechanical Timer AssemblyFigure 21
Model 9000/9100/9500239000/9100/9500 Electro Mechanical Timer AssemblyItem Quantity Part Number Description1 1 13870-03 timer housing assembly.2 1 178
Model 9000/9100/9500 249000/9100/9500 Power HeadFigure 22
Model 9000/9100/9500259000/9100/9500 Power HeadItem Quantity Part Number Description1 2 18728 nut, clip #8-322 1 11838 power cord, 6' U.S. 120V11
Model 9000/9100/9500 269000 Control Valve AssemblyFigure 23
Model 9000/9100/9500279000 Contro l Va lve Assemb ly Item
Model 9000/9100/9500 289100 Control Valve AssemblyFigure 24
Model 9000/9100/9500299100 Control Valve AssemblyItem Quantity Part Number Description1 1 40688 valve body assembly2 4 15137 screw, hex washer #10-24
Model 9000/9100/95003Job Specifications SheetJob Number ___________________________________________Model Number ____________________________________
Model 9000/9100/9500 309500 Control Valve AssemblyFigure 25Item Quantity Part Number Description1 1 16919-01 valve body 9500 NPT, mechanical base1691
Model 9000/9100/9500319500 Brine Valve Systems (1600 and 1700 Series)Figure 26Figure 27Item Quantity Part Number Description1 1 16922 bracket, brine v
Model 9000/9100/9500 329000/9100/9500 Second Tank AssembliesFigure 28Figure 29Figure 30
Model 9000/9100/9500339000/9100/9500 Second Tank AssembliesItem Quantity Part Number Description9000 second tank assembly1 4 14202-01 screw, hex head
Model 9000/9100/9500 349000/9100/9500 Meter AssembliesFigure 31Figure 32Figure 33
Model 9000/9100/9500359000/9100/9500 Meter AssembliesItem Quantity Part Number Description9000 meter assembly1 1 60086 3/4" meter assembly, stand
Model 9000/9100/9500 369000/9100 Bypass ValveFigure 34Item Quantity Part Number Description1 1 60040SS 3/4" bypass valve NPT60040-10 3/4" b
Model 9000/9100/9500372310 Safety Brine ValveFigure 35Item Quantity Part Number Description1 1 600142310 safety brine valve2 1 600682310 float assembl
Model 9000/9100/9500 389500, 2350 Safety Brine ValveFigure 36Item Quantity Part Number Description1 1 600382350 safety brine valve1A 1 610242350 actu
Model 9000/9100/9500392300 Safety Brine ValveFigure 37Item Quantity Part Number Description1 1 60027-FFA2300 safety brine valve, fitting facing arm600
Model 9000/9100/9500 4General and Commercial Installation ChecklistWater Pressure A minimum of 25 lbs of water pressure is required for regeneration
Model 9000/9100/9500 40Water Conditioner Flow DiagramsIn Service PositionTanks SwitchingFigure 38: In Service PositionFigure 39: Tanks Switching, Met
Model 9000/9100/950041BackwashBrine DrawFigure 40: Backwash PositionFigure 41: Brine Draw
Model 9000/9100/9500 42Slow RinseRapid RinseFigure 42: Slow RinseFigure 43: Rapid Rinse
Model 9000/9100/950043Brine Tank Fill PositionIn Service, Tanks SwitchedFigure 44: Brine Tank Fill PositionFigure 45: In Service, Tanks Switched
Model 9000/9100/9500 44TroubleshootingPROBLEM CAUSE CORRECTION1. Softener fails to regenerate. A. Electrical service to unit has been interrupted. B.
Model 9000/9100/950045General Service HintsProblem: Softener delivers hard waterPROBLEM CAUSE CORRECTION8. Softener fails to draw brine. A. Drain l
Model 9000/9100/9500 46Mechanical Timer Valve WiringFigure 46TM - TIMER MOTORVDM - VALVE DRIVE MOTORSW1 - TIMER HOMING SWITCHSW2 - TIMER PROGRAM SWIT
Model 9000/9100/950047ET Timer Valve WiringTwin Unit Meter/Timeclock/Sensor RegenerationFigure 47TB1 - HIGH VOLTAGE TERMINAL BLOCKTB2 - LOW VOLTAGE TE
Model 9000/9100/9500 48SE Timer Valve WiringFigure 48CB1 - SE TIMERT1 - 24V TRANSFORMERTM - 3/4" TURBINE FLOW METER (OPTIONAL)PWM - 1.0" PA
Model 9000/9100/9500499000 Control DimensionsFigure 49
Model 9000/9100/95005Equipment ConfigurationFigure 1:9000/9100Figure 2:9500inletoutletbypass valveadapter clipsmain control valvetank two adaptertank
Model 9000/9100/9500 509100 Control DimensionsFigure 50
Model 9000/9100/9500519500 Control DimensionsFigure 51
Model 9000/9100/9500 52Meter Flow Data9000Figure 52:9000 Meter Flow Data
Model 9000/9100/95005391009500Figure 53:9100 Meter Flow DataFigure 54:9500 Meter Flow Data
Model 9000/9100/9500 54Injector Flow Data9000/9100Figure 55:9000/9100—1600 Series Injectors
Model 9000/9100/9500559500Figure 56:9500—1600 Series InjectorsFigure 57:9500—1700 Series Injectors
P/N 40944 Rev. A 01/03
Model 9000/9100/9500 6General and Commercial Installation Checklist1. Place the softener tank where you want to install the unit. NOTE:Be sure the ta
Model 9000/9100/9500716. Cycle timer into backwash position. Turn manual knob so that the micro switch rides on the first set of pins.— In this positi
Model 9000/9100/9500 8NOTE:Two motors are available:1/15 RPM has 82 minute Regeneration Time.1/30 RPM has 164 minute Regeneration Time. See Figure 5.
Model 9000/9100/95009Regeneration Cycle Program Setting ProcedureSetting the Regeneration Cycle ProgramThe Regeneration cycle program on the water con